It looks like you have the DF1 side configured, you should be able to confirm if data is being exchanged by looking at the node monitor. This is setup using the AOP and that data is exchanged to the tags configured in the configuration software. Then on the ethernet/IP side the PLC is reading and writing the data off of the Linking device. The linking device is a DF-1 is reading and writing the IO on the SLC plc using the instructions. The Linking device is not a transparent ethernet/IP to DF1 gateway. If you are not using an Allen Bradly Processor for the final step I was suggesting the AB7072 as an alternative to the HMS-EN2SE-R. The HMS-en2se-R requires you to use Studio 5000 and a compatible PLC on the ethernet/IP interface. “Basically I need to connect the SLC 5/03 with a CompactLogix L18…(just for trials)…as the final approach is connect directly the SLC 5/03 with the kepserverEX (OPC server of our MES system).” Perhaps there is a misunderstanding between us here. The setup for the DF1 side is the same but the video will not cover the Studio5000/AOP specific tasks like Tags. The EN2SE is very similar to the ab7072 communicator, the en2se add some features like built in tag support and is programed via ethernet with the AOP. We have the following video for a communicator that goes through this process. This being said I have no issues helping with your questions.

Kepserverex configuration file driver#

Kepware has a driver to read directly from DF1 protocol.īefore answer you questions I have a disclaimer this forum is run by our support team here in the United States and I recommend you reach out to your local distributor or local HMS sales team to to ensure you are picking the right product. So I dont understand why you propose this new comunicator if I need a EDS file to configure it as a generic module in the logix5000. My proposal is not use any rockwell plc as a pasarell between SLC and kepware.

kepserverex configuration file

Kepserverex configuration file manual#

In this case do you have a manual user or video to implement this solution?Ībout you solution to change the device to AB7072 I am a little bit confused. Just a trial, and take the opportunity of the EN2SE offers, I am thinking in use a compact logix to read the data from the SLC 5/03, and use the allen bradley driver from the SCADA to connect the compactLogix. So after you mail I have the next questions.

Kepserverex configuration file trial#

The mistake it was, as in the lab I have some compactlogix, it would like to run some trial and connect the SLC with the compact with the EN2SE as it is the module that we bought. We have a kepserverEX as a third party OPC to connect with out MES system (Ignition Scada) and now we need to connect some SLC 5/03 plc with kepware. First of all, sorry to use other issue for asking about the connection the SLC5/03 with kepserverEx.